<?xml version="1.0" standalone="yes"?>
<?xml-stylesheet type="text/xsl" href="..\..\XSLTemplates\NVSStyleSheet.xsl"?>
<Parameter>
<ParameterFamily>gc</ParameterFamily>
<LongName>
orthog_adjust
</LongName>
<Name>
ortho
</Name>
<AppliesTo>
<UnnumberedList>
<ListItem><TextApplies>All</TextApplies></ListItem>
</UnnumberedList>
</AppliesTo>
<Description>
<DescriptionText><text>
This parameter rotates the two imaging axis (mainscan and subscan) relative to
one another.  It is used to make the sides of an image square.  This parameter
is calibrated during factory integration and normally should not change after
this.  Adjustments should be made with advice from factory integrators.
</text></DescriptionText>
<DescriptionText><text>
A positive angle will rotate the mainscan (around drum) axis in a
counter-clockwise direction.
</text></DescriptionText>
</Description>
<Type>
integer
</Type>
<Default>
<UnnumberedList>
<li>0</li>
</UnnumberedList>
</Default>
<Range>
<UnnumberedList>
<li>-32767 to 32767 [microrads]</li>
</UnnumberedList>
</Range>
<ArraySize>
</ArraySize>
<Notes>
<DescriptionText><text>
</text></DescriptionText>
</Notes>
<Partition>
cal
</Partition>
<SeeAlso>
<UnnumberedList>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<li><Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 0 Error Index</LinkTitle></Link></li>
<li><Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 0 Command Index</LinkTitle></Link></li>
<li><Link><LinkAddress>..\..\ShowAllNVS.htm</LinkAddress><LinkTitle>Firmware 0 NVS Index</LinkTitle></Link></li>
</OtherLinks>
<Updated>
Updated: Wed Jul 16 19:36:48 2008 PST
</Updated>
<Links>
</Links>
</Parameter>